Filter Results By:

Products

Applications

Manufacturers

Current Meters

Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.


Showing results: 481 - 492 of 492 items found.

  • PXI-6238, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Hybrid, Multifunction I/O

    779624-01 - NI

    8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6238 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6238 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6238 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6239, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module

    779626-01 - NI

    8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6239 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6239 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6239 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6236, 4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module

    779622-01 - NI

    4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6236 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6236 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6236 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • Astronomy Solutions

    Thales SESO, SAS

    For more than 40 years, Thales has delivered high accuracy optics for ground-based Astronomy all around the world. These optics range from single, but challenging, unmounted optical components up to fully integrated opto-mechanical systems. Our design heritage and past experience in this field cover the design, manufacture and AIT activities of many optics and sub-assemblies used in Telescope instrumentation, such as focal plane assemblies as well as the direct production of telescope mirrors themselves. Several major achievements of Thales ground-based Astronomy products were the Optical wide field corrector for the Dark Energy Survey (lien), the Reference Body for future Deformable Secondary Mirror of the VLT (lien) and different challenging spectrograph optics (Collimator and Cameras) for different Observatories (lien). One advantage Thales has with this activity is that most part of the manufacturing steps involved (i.e. opto-mechanical design, milling/grinding, lightening, polishing and coating) are directly under our control in our own facility. Our current capabilities for the production of optics for ground-based Astronomy are from a few centimeters size up to 2 meters. Thanks to the continuous efforts in R& D and investments into new production machines, Thales is now ready for future industrial challenges including the optical production of some key elements of the E-ELT, GMT and TMT programs.

  • Transformer Turns Ratio Meter

    TTRM 102 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types.  TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

  • Battery Voltage Recorder

    BVR Series - IBEKO Power AB

    Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.

  • Transformer Turns Ratio Meter

    TTRM 101 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

  • Fused Test Probes with Silicone Test Leads

    AL-57FL - Standard Electric Works Co., Ltd

    ● AL-57FL is an ideal tool which shows the indication of live voltage even with blown fuse.● 2 replaceable fast-acting fuses are built-in. The specs of the fuses are 1000V, 11A with internal rating of 20kA AC/DC.● Provide additional testing protection.● Help to prevent a possible mis-indication when there is voltage present.● CAT III 1000V, CAT IV 600V, 10A with protective cover.● 2mm probe tips, removable 4mm brass caged banana probe tips are also included.● Include High-quality silicone test leads, 1.5 meter long.● Wipe the fused test probes and silicone test leads periodically with a damp cloth and detergent. Do not use abrasives or solvents.● Operating temperature: -20 °C to +50 °C (-5 °F to 120 °F)● One year warranty● Can't be used on current mode with blown fuse.● Rating : EN 61010-031 CAT Ⅲ 1kV 10A / CAT Ⅳ 600V 10A

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Power Phase Converter Single phase 220VAC to 3 phase 380VAC Converter

    SDT-40KW - Zhejiang Sandi Electric Co., Ltd

    SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can?謒?apply for the three-phase electric because of space limitation.Features1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter?謒?usage, which reduced the cost of equipment investment, easy to connect wires and control.3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.9) High conversion efficiency, high instantaneous power and low load loss.10) The input voltage, output voltage, frequency and phase can be custom made.SpecificationModel SDT-40KWIsolation mode Low Frequency TransformerAC InputRated voltage (Vac) 240V single-phase 60HZVoltage range (Vac) 190-270VInput current (A) 167AAC OutputRated power (KW) 40KWRated voltage 240V ± 2%Output phases Three-phase with Neutral wires (L1, L2, L3 + N)Rated current (A) 96AOutput frequency 60Hz ±0.05 (50HZ can be set)Waveform Pure sine waveVoltage accuracy Load balancing≤1%、Unbalanced load≤5%Waveform distortion rate (THD) Linear load≤2%、Nonlinear load≤3%Dynamic Response 5%,≤50ms (load 0~100%)Power Factor (PF) 0.99Inverter Efficiency ≧85%Electrical insulation properties 2000Vac、1 MinuteProtection FunctionOverload Ability 150%、10sProtection Input under voltage, overvoltage, output over-current, short circuit, overheating etc.Display LCD+LEDMethod of working Working continuouslyCooling method Intelligent fan coolingShort-circuit protection No automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protection IP20 (indoor)Working Altitude(m) ≤3000mWorking temperature (℃) -20~+50℃Relative humidity (℃) -25~+85℃Noise (1 meter) ≤60dBReference size: (W x D x H) 750×750×1480mmReference net weight (Kg) 340Kg

Get Help